<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>6477F5 &#8211; A24 Italia</title>
	<atom:link href="https://www.autotech24.it/tag-prodotto/6477f5/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.autotech24.it</link>
	<description>Ricambi Citroën Peugeot</description>
	<lastBuildDate>Fri, 27 Nov 2026 03:05:20 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>
	<item>
		<title>Air conditioning pipe Citroën C4 Picasso 9685499580 6477F5</title>
		<link>https://www.autotech24.it/air-conditioning-pipe-citroen-c4-picasso-9685499580-6477f5/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Fri, 27 Nov 2026 03:05:19 +0000</pubDate>
				<guid isPermaLink="false">https://www.autotech24.it/air-conditioning-pipe-citroen-c4-picasso-9685499580-6477f5/</guid>

					<description><![CDATA[Stellantis CITROEN PEUGEOT 9685499580 6477F5 NFP]]></description>
										<content:encoded><![CDATA[<p>Refrigerant pipe for CITROEN C4 PICASSO vehicles with 5FS engine</p>
<h3>Part description</h3>
<p>This used <strong>air conditioning pipe for Citroën C4 PICASSO with 5FS engine</strong> carries refrigerant through the air conditioning circuit. It is intended as a replacement part when replacing damaged or leaking pipework. The source materials list it under numbers <strong>9685499580 and 6477F5</strong>, which are important when selecting the matching version.</p>
<p>A correctly selected and tightly fitted pipe is essential for reliable air conditioning operation. Before purchasing, compare the original part number as well as its shape, connections and mounting points; the model name alone may not distinguish all air conditioning pipework variants.</p>
<h3>Technical information</h3>
<ul>
<li><strong>Manufacturer</strong>: not specified; the source materials list the designation Stellantis CITROEN PEUGEOT</li>
<li><strong>Model</strong>: Citroën C4 PICASSO</li>
<li><strong>Engine</strong>: 5FS</li>
<li><strong>Part type</strong>: air conditioning refrigerant pipe</li>
<li><strong>Condition</strong>: used part</li>
<li><strong>Additional numbers</strong>: not specified</li>
<li><strong>Additional designation from the source materials</strong>: NFP</li>
</ul>
<h3>Product codes</h3>
<ul>
<li><strong>Product codes</strong>: 9685499580, 6477F5</li>
<li><strong>Model</strong>: Citroën C4 PICASSO</li>
</ul>
<h3>Installation recommendations</h3>
<p><strong>The following procedure is a general guide to replacing air conditioning pipework.</strong> Exact access to the part, the method for disconnecting the connections and the installation requirements depend on the specific vehicle version. The air conditioning circuit may be pressurised even when the engine is off. Have refrigerant recovery, evacuation, charging and leak testing carried out by a specialist facility with suitable equipment; refrigerant must not be released into the atmosphere.</p>
<p><strong>1) Before installation</strong></p>
<ul>
<li>Compare the product numbers, pipe routing and bends, length, connections and mounting points with the old part.</li>
<li>Inspect the used part, paying particular attention to dents, cracks, scuffs, corrosion and deformed connections.</li>
<li>Check the sealing surfaces and ensure the openings are clean. If internal contamination or a leak is suspected, have the part professionally assessed before installation.</li>
<li>Identify the cause of the original pipe&#8217;s damage to prevent the fault from recurring after replacement.</li>
</ul>
<p><strong>2) Required tools and materials</strong></p>
<ul>
<li>Standard hand tools suitable for the connections used, and a torque wrench for tightening in accordance with the service documentation.</li>
<li>Safety glasses, gloves, clean lint-free cloths and suitable plugs for open connections.</li>
<li>New seals suitable for the specific connections and air conditioning system, as specified by the manufacturer.</li>
<li>Professional equipment for refrigerant recovery, leak testing, evacuation and air conditioning recharging.</li>
</ul>
<p><strong>3) Step-by-step installation procedure</strong></p>
<ol>
<li>Secure the vehicle against movement, switch off the engine and ignition, and allow the work area to cool.</li>
<li>Refer to the service documentation to determine the access required to reach the pipe and the safety measures for the specific vehicle version.</li>
<li>Have the refrigerant recovered by a qualified professional. Before opening the circuit, verify that it is safe to disconnect.</li>
<li>Remove only the components necessary to access the pipe. Record the original pipe routing and the position of its brackets.</li>
<li>Clean around the connections to prevent dirt from entering the circuit when they are disconnected.</li>
<li>Release the mounts and connections without twisting the adjacent pipework. Do not pry the connections apart across the sealing surfaces.</li>
<li>Remove the original part and immediately seal the open ends of the circuit with clean plugs.</li>
<li>Compare the two parts once more. Check the mating surfaces and prepare suitable new seals in accordance with the manufacturer&#8217;s procedure.</li>
<li>Fit the replacement pipe along the original route without forcing it to bend or placing it under stress. Initially fit the connections loosely so they can seat correctly.</li>
<li>Secure the pipe and tighten the connections in accordance with the service documentation. Check that the pipe does not rub against surrounding components and is correctly secured in its brackets.</li>
<li>Refit the removed components and have the prescribed leak test, evacuation and circuit charging carried out according to the specifications for the specific vehicle.</li>
</ol>
<p><strong>4) Post-installation checks and function verification</strong></p>
<ul>
<li>After charging, check the disconnected connections and replaced pipe for leaks using a suitable service method.</li>
<li>With the air conditioning running, check the cooling performance, unusual noises and any vibration in the pipework.</li>
<li>After a short test drive, inspect the mounting points again and check that the pipe does not come into contact with any surrounding parts.</li>
</ul>
<p><strong>5) Common installation mistakes and how to avoid them</strong></p>
<ul>
<li><strong>Confusing it with similar pipework:</strong> compare both the numbers and the physical design, especially the ends and brackets.</li>
<li><strong>Reusing damaged seals:</strong> use suitable new seals and protect them from being pinched during assembly.</li>
<li><strong>Allowing moisture and dirt to enter:</strong> plug open connections immediately and keep the time the circuit is open to a minimum.</li>
<li><strong>Installing under stress or overtightening connections:</strong> the pipe must seat naturally; follow the specified tightening procedure.</li>
<li><strong>Skipping leak testing and evacuation:</strong> simply topping up the refrigerant is not a substitute for properly completing an air conditioning repair.</li>
</ul>
<h3>Reasons why the part may become damaged</h3>
<p>The following are general causes of damage to air conditioning pipework; they do not describe the condition of the part being offered:</p>
<ul>
<li><strong>Corrosion caused by moisture and road salt</strong>, particularly in areas where dirt accumulates.</li>
<li><strong>Chafing against surrounding components</strong> due to a loose bracket or incorrect pipe routing.</li>
<li><strong>Vibration and fatigue cracks</strong> caused by prolonged stress or installation under tension.</li>
<li><strong>Mechanical damage</strong> during an accident, handling or repairs to surrounding components.</li>
<li><strong>Damage to connections and sealing surfaces</strong> caused by unsuitable tools, overtightening or dirt in the joint.</li>
<li><strong>Seal deterioration</strong>, which can cause refrigerant to leak from a joint even if the pipe itself has not cracked.</li>
</ul>